This test is performed to characterize thermal durability of cell by exposing at low and high temperature environment alternately to cause expansion and contraction of cell components.
6.2.2.1 Test
Either of the test procedures specified in 6.2.2.1.1 or 6.2.2.1.2 shall be performed according to the agreement between the customer and the manufacturer.
6.2.2.1.1 Test without electrical operation
The test shall be performed as follows.
a) Adjust the SOC of cell to 100 % for BEV application, and to 80 % for HEV application in accordance with 5.3.
b) Perform the temperature cycling in accordance with ISO 16750-4 as shown in Table 4. The minimum operating temperature shall be –40 °C or Tmin specified by the manufacturer and the maximum operating temperature shall be 85 °C or Tmax specified by the manufacturer. Perform 30 test cycles as specified.
Table 4 – Temperatures and time duration for temperature cycling
6.2.2.1.2 Test with electrical operation
The test shall be performed as follows.
a) Adjust the SOC of cell to 80 % for BEV application, and to 60 % for HEV application in accordance with 5.3.
b) Perform the temperature cycling in accordance with ISO 16750-4 as shown in Table 5. The minimum operating temperature shall be –20 °C and the maximum operating
temperature shall be 65 °C.
c) Perform the following current profiles during each temperature cycle:
– BEV current profile in accordance with Figure 4 and Table 6;
– HEV current profile in accordance with Figure 6 and Table 7.
d) Perform 30 test cycles as specified.
Table 5 – Temperatures and time duration for temperature cycling
Figure 4 – BEV current profile for temperature cycling
Table 6 – Test steps and BEV current profile
Figure 5 – SOC level over all test cycles – BEV application
Figure 5 shows the SOC level over the cumulative test time for a BEV application.
Figure 6 – HEV current profile for temperature cycling
Table 7 – Test steps and HEV current profile
6.2.2.2 Test results
The following shall be measured and recorded as test results:
· cell voltage and capacity at the beginning and at the end of the test;
· conditions of cell at the end of test in accordance with the description specified in Clause 7;
· cell voltage, current and temperature shall be continuously recorded during each cycle.
|